Function: Designed for bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system used in conjunction with a UTT Manufacturing structural attachment fitting, and joined together with a bracing pipe element forms a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer’s installation instructions.
Type: Sprinkler Pipe Sch 10,Sch 40,GB/T 3091,JIS G3454
Size: Pipe size 2"(50) thru 8"(200)
Material: Carbon steel
Finish: Electro-galvanized
Approvals:
UL Maximum Design Load | |||||
Pipe Size | lbs. | KN | Wt. Each | ||
1"(25mm) Brace Pipe | |||||
lb. | kg | ||||
2 | (50) | 680 | (3.02) | 2.33 | (1.06) |
2½ | (65) | 680 | (3.02) | 2.42 | (1.1) |
3 | (80) | 680 | (3.02) | 2.55 | (1.16) |
4 | (100) | 680 | (3.02) | 2.73 | (1.24) |
5 | (125) | 1090 | (4.84) | 3.92 | (1.78) |
6 | (150) | 1370 | (6.09) | 4.29 | (1.95) |
8 | (200) | 1370 | (6.09) | 4.93 | (2.24) |
FM Maximum Design Load | |||||||
Pipe Size | Horizontal load ratings installation angle 30°-44° | Horizontal load ratings installation angle 45°-59° | Wt. Each | ||||
1"(25mm) Brace Pipe | |||||||
Ibs. | kN | Ibs. | kN | lb. | kg | ||
2 | (50) | 1070 | (4.75) | 1440 | (6.40) | 0.92 | (0.42) |
2½ | (65) | 840 | (3.73) | 1120 | (4.98) | 1.01 | (0.46) |
3 | (80) | 1030 | (4.58) | 1560 | (6.93) | 1.08 | (0.49) |
4 | (100) | 650 | (2.89) | 890 | (3.95) | 1.21 | (0.55) |
6 | (150) | 830 | (3.69) | 1250 | (5.56) | 1.52 | (0.69) |
8 | (200) | 880 | (3.91) | 1150 | (5.11) | 1.81 | (0.82) |
Step 1 | Step 2 | Step 3 |
![]() | ![]() | ![]() |
Install:
Install the pipe clamp to the pipe, then install the bolts and nuts as the shown picture. The accessories of UTT20 use the sch40 1-inch pipe,The nuts torque of UTT 20 need to reach 100~115N·M to make all green marking lines visible in the bolts. After the installation of bolts & nuts and other accessories, the pipe must be clamped to the bottom of the accessories. |
Function: Designed for bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system used in conjunction with a UTT Manufacturing structural attachment fitting, and joined together with a bracing pipe element forms a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer’s installation instructions.
Type: Sprinkler Pipe Sch 10,Sch 40,GB/T 3091,JIS G3454
Size: Pipe size 2"(50) thru 8"(200)
Material: Carbon steel
Finish: Electro-galvanized
Approvals:
UL Maximum Design Load | |||||
Pipe Size | lbs. | KN | Wt. Each | ||
1"(25mm) Brace Pipe | |||||
lb. | kg | ||||
2 | (50) | 680 | (3.02) | 2.33 | (1.06) |
2½ | (65) | 680 | (3.02) | 2.42 | (1.1) |
3 | (80) | 680 | (3.02) | 2.55 | (1.16) |
4 | (100) | 680 | (3.02) | 2.73 | (1.24) |
5 | (125) | 1090 | (4.84) | 3.92 | (1.78) |
6 | (150) | 1370 | (6.09) | 4.29 | (1.95) |
8 | (200) | 1370 | (6.09) | 4.93 | (2.24) |
FM Maximum Design Load | |||||||
Pipe Size | Horizontal load ratings installation angle 30°-44° | Horizontal load ratings installation angle 45°-59° | Wt. Each | ||||
1"(25mm) Brace Pipe | |||||||
Ibs. | kN | Ibs. | kN | lb. | kg | ||
2 | (50) | 1070 | (4.75) | 1440 | (6.40) | 0.92 | (0.42) |
2½ | (65) | 840 | (3.73) | 1120 | (4.98) | 1.01 | (0.46) |
3 | (80) | 1030 | (4.58) | 1560 | (6.93) | 1.08 | (0.49) |
4 | (100) | 650 | (2.89) | 890 | (3.95) | 1.21 | (0.55) |
6 | (150) | 830 | (3.69) | 1250 | (5.56) | 1.52 | (0.69) |
8 | (200) | 880 | (3.91) | 1150 | (5.11) | 1.81 | (0.82) |
Step 1 | Step 2 | Step 3 |
![]() | ![]() | ![]() |
Install:
Install the pipe clamp to the pipe, then install the bolts and nuts as the shown picture. The accessories of UTT20 use the sch40 1-inch pipe,The nuts torque of UTT 20 need to reach 100~115N·M to make all green marking lines visible in the bolts. After the installation of bolts & nuts and other accessories, the pipe must be clamped to the bottom of the accessories. |